Interface Modules.

Home Up PD3150. PD3234. PD3240. PD3280. PD3260. PD3940. PD3930. PD3920. PD3250. PD3230. PD3221. PD3120.

 

Interface Modules

 

 

Below are a list of the interface modules available. All these modules are designed to be used with the Fieldbus P-NET (refer to Fieldbus). The modules provide the ability to interface with almost any process sensor or control, providing the means of distributing control/intelligence. The modules can be supplied as separate units for customers to build their own system or will be used by us to provide a complete system to suit our customers requirements.

Also detailed below are the communication modules, which provide the ability to connect a P.C. using VIGO to the P-NET or a RS232 devices to P-NET.

To obtain further information on any of the modules below, please use the Information request Form below.

Interface Modules: ( follow link to see more detail on individual modules)

 

PD3100 Digital I/O DC Interface:    32 Input/Output Channels, which can be connected 

                                                       directly to 24 VDC equipment.

 

PD3120 Digital I/O DC Interface:    16 Input/Output Channels for 24 VDC, also includes an 

                                                        internal user programmable calculator channel for local 

                                                        control.

 

PD3150 Digital I/O DC Matrix:    32 Input/Output Channels, which can be connected directly 

                                                    to 24 VDC equipment. 16 off Sink and 16 off Source making 

                                                    module suitable for matrix connections.

 

PD3221 Universal Process Interface:     6 Digital Input Channels (4 off Input/Output), 2 

                                                             Analogue Inputs (current/voltage/PT-100), 1 Analogue 

                                                             Output. Also includes calculator, pulse processor and 

                                                              PID channels.  

 

PD3230 Weight Transmitter:        1 High resolution weight input channel (suitable for paralleling  

                                                    up to 10 x 600 Ohm Standard load cells. 6 Digital Input 

                                                    Channels (4 off Input/Output) and Calculator channel. Can be 

                                                    used to perform Belt Weight functions. 

                                                    PD3235 also available for use with up to 10 x 300 Ohm load 

                                                    cells.

 

PD3234 Weight Transmitter:        1 High resolution weight input channel (suitable for paralleling  

                                                    up to 10 x 600 Ohm Semiconductor load cells. 6 Digital 

                                                    Input Channels (4 off Input/Output) and Calculator channel. 

                                                    Can be used to perform Belt Weight functions.

 

 PD3240 Analogue Interface:        16 analogue Input channels ( 0-20 & 4-20mA) provides the 

                                                     ability to convert measurement directly into Engineering Units.

 

PD3250 Analogue Interface:        16 analogue Input channels for voltage ( 0-100mV or 

                                                    Thermocouple inputs) and 1 PT-100 Input. The module also 

                                                    provides the ability to convert voltage measurement directly 

                                                    into Engineering Units.

 

PD3260 Power Monitor:             1 Power Monitor channel, 1 Generator Switch, 1 Thyristor 

                                                   Switch and 8 Digital Input/Outputs also includes an internal      

                                                   user programmable calculator channel for local control.

 

PD3280 P-NET Repeater:          3  RS485 P-NET Interfaces , used to provide galvanically

                                                   isolated extension between P-NET sections, making

                                                   addressing of modules between sections transparent.

 

PD3285 P-NET Repeater:          3  RS485 P-NET Interfaces , used to provide galvanically

                                                   isolated extension between P-NET sections, making

                                                   addressing of modules between sections transparent. Also 

                                                   provides 1 interface for duplex optical fibre capable of 

                                                   extending the P-NET up to 3.1km.

 

PD3940 RS232/P-NET:           module providing communication between P-NET and RS232 devices such as printers 

                                                 barcode readers.

 

Communication Modules( follow link to see more detail on individual modules)

 

PD3920 PC/P-NET Interface:    ISA half size expansion board, allowing PC to connect to 

                                                  P-NET Fieldbus.

 

PD3930 Parallel PC/P-NET:     module providing ability to connect PC to P-NET Fieldbus via 

                                                   PC Parallel Port.

 

 

 

 

  

 